| Item | Technical Index | Specification | 
|  | 
| Input | Input voltage | 1AC 220~240V±15% | 
| 3AC 220~240V±15% | 
| 3AC 380~460V±15% | 
| Input frequency | 50/60Hz±5% | 
| Output | Output voltage | 0~rated input voltage | 
| Output frequency | 0~6000Hz | 
| Control Features | Control mode | V/f control | 
| Sensorless vector control | 
| Torque control | 
| Overload capacity | 150% / 120s, 160% / 60s, 180% / 10s, 200% / 1s. | 
| Frequency accuracy | Digital setting: 0.01Hz | 
| Analog setting: maximum frequency ×0.05% | 
| Starting torque | 0.5Hz/180% (SVC); 1Hz/150% (V/f) | 
| Speed control precision | ±0.5% (SVC) | 
| Carrier frequency | temperature and load characteristics 0.5~16.0kHz, automatically
adjusted according to | 
|  | 
| Frequency setting mode | Digital setting, analog setting, pulse frequency setting, serial
communication setting, multi-step speed setting & simple PLC, PID
setting, etc. These frequency settings can be combinated & switched
in various modes. | 
|  | 
|  | 
|  | 
| Torque boost | Automatically torque boost; manually torque boost: 0.1%~30.0 | 
|  | 
| Operation command mode | Keypad control | 
| Terminal control | 
| Serial communication control (Modbus) | 
| Acceleration/deceleration mode | Straight line/S curve; four kinds of acceleration/deceleration
time, range: 0.0s~65000s | 
|  | 
| V/f curve | Three types: linear, multiple point and square type (1.2 power, 1.4
power, 1.6 power, 1.8 power, square) | 
|  | 
| Acceleration/deceleration mode | Straight line/S curve; four kinds of acceleration/deceleration | 
| time, range: 0.0s~65000s | 
| Braking unit | build-in standard. | 
| DC braking | Braking time: 0.0s~25.0s | 
| DC braking when starting and stopping | 
| DC braking frequency: 0.0Hz~maximum frequency | 
| Simple PLC & multi-step speed operation | It can realize a maximum of 16 multi-step speeds running via the
built-in PLC or control terminal. | 
|  | 
| Built-in PID | Built-in PID control to easily realize the close loop control of
the process parameters (such as pressure, temperature, flow, etc.) | 
|  | 
|  | 
| Automatic voltage regulation | Keep output voltage constant automatically when input voltage
fluctuating | 
|  | 
| Control Function | Timing/length/counting control | Timing/length/counting control function | 
|  | 
| Over-voltage & over-current stall control | Limit current & voltage automatically during the running process,
prevent frequent over-current & over-voltage tripping | 
|  | 
| Torque control | Torque control without PG | 
| Wobble frequency control | Multiple triangular-wave frequency control, special for textile | 
| Fault protection function | Comprehensive protections include over-current, over-voltage,
under-voltage, overheating, default phase, overload, shortcut,
etc., can record the detailed running data while failures happen. | 
|  | 
|  | 
|  | 
| Input/output terminals | Communication terminals | Build-in standard RS485 communication interface, support MODBUS-RTU
communication protocol | 
|  | 
| Input terminals | Programmable digital input: 7 multifunctional inputs, one can be
work as high speed pulse input.3 programmable analog input:AI1,
AI2, AI3: 0~10V / 4~20mA | 
|  | 
|  | 
| Output terminals | 2 relay outputs, | 
| 2 open collector outputs, | 
| 2 anaalog outputs, 0~10V / 4~20mA | 
| Human machine interface | LED display | Display frequency setting, output frequency, output voltage,output
current, etc. Two lines display | 
|  | 
| Environment | Ambient temperature | -10~50°C, without direct sunshine. | 
| Humidity | 90%RH or less (non-condensing) | 
| Altitude | ≤1000M: output rated power, >1000M: output derated | 
| Storage temperature | -20~60°C | 
|  | 
|  |  |  | 
| No | Items | KD330 | 
| 1 | Reliable hardware | Only first-class componens are built-in. | 
| 2 | Rubust design | IGBT current > 2 times of inverter output current | 
| Capacitor > 50uF/A | 
| 3 | Electrostatic testing | 1. Under contact condition -- without failure under 5000V. | 
| 2. Noncontact conditions -- without failure under 10000V. | 
| 4 | High overload capacity | 150% / 120s, 160% / 60s, 180% / 10s, 200% /1s | 
| Smart start / stop mode | Acceleration / Deceleration time can be set as 0.0s, the inverter
starts and stops the motor as fast as possible without failure. | 
|  | 
| 5 | PCB aging test | 100% test, 50°C, 12 hours. | 
| Finished products aging test | 100% test, 50°C, 24 hours. | 
| 6 | Loading test | 1. After manufacturing. | 
| 2. After aging test. | 
| Two times, 100% tested: | 
| 7 | LED display | >7,5kW, two lines parameters dispaly, convenient for
commissioning and operating. | 
|  | 
| 8 | Grouped pulse testing | Without failure under 4500V (better EMC performance). | 
|  | 
| 9 | Big start torque | 0.5Hz/150% (V/f), 1Hz/150% (SVC) | 
| 10 | EMC filter | C3 level EMC filter build-in standardly |