Sign In | Join Free | My burrillandco.com
Home > Motor Frequency Converter >

High Starting Torque Ac Frequency Converter , Motor Frequency Inverter

    Buy cheap High Starting Torque Ac Frequency Converter , Motor Frequency Inverter from wholesalers
     
    Buy cheap High Starting Torque Ac Frequency Converter , Motor Frequency Inverter from wholesalers
    • Buy cheap High Starting Torque Ac Frequency Converter , Motor Frequency Inverter from wholesalers

    High Starting Torque Ac Frequency Converter , Motor Frequency Inverter

    Ask Lasest Price
    Brand Name : Kinda
    Model Number : KD330
    Price : Negotiable
    Delivery Time : 3~8 Day
    Payment Terms : TT
    Supply Ability : Adequate inventory
    • Product Details
    • Company Profile

    High Starting Torque Ac Frequency Converter , Motor Frequency Inverter

    Kinda Motor Frequency Converter Applied in Hoist Ppplications

    1, Features of traditonal system
    (1) The traditional system works at heavy load for long time, forward and reverse run frequently, the lifetime of the
    system is short;
    (2) High failure ratio.
    (3) Low efficiency, the power factor is less than 0.8.
    (4) The safety performance is bad.

    2, Requests for frequency inverters (VFD)
    (1) Big output torque at low frequency, it should run smoothly during working.
    (2) Big overload capacity.


    (3) Less failure ratio, run stably.
    (4) Braking unit and braking resistor should be added.

    3, Real application (Tower crane)
    3. 1 system introduction

    The hoist motor in the system is 55kW/380V, the load type is constant torque, to consider its heavy duty characteristic,
    the frequency inverter should be selected two sizes higher as below:

    3.2 system diagram

    3.3 control logic

    (1) The tower crane control system provide the forward and reverse signals, while MI1 and DCM closed, the tower
    crane runs forwardly, and while MI2 and DCM closed, the tower crane runs reversely:

    (2) The running speed of crane is controlled by ON/OFF conditions of MI3, MI4 and MI5, details as below:

    MI5MI4MI3Speed
    OFFOFFOFFSpeed 0 (FD-00)
    OFFOFFONSpeed 1 (FD-01)
    OFFONOFFSpeed 2 (FD-02)
    OFFONONSpeed 3 (FD-03)
    ONOFFOFFSpeed 4 (FD-04)
    ONOFFONSpeed 5 (FD-05)

    (3) The inverter output a fault signal to the crane control system, while fault happen, the system will brake and stop immediately.

    (4) There is an output FDT1 (controlled by F8-19 and F8-20) ON/OFF signal, while the inverter runs to the setting
    frequency, this signal will control the brake to open, to avoid the reverse run happen.

    3.4 autotuning

    For this kind of heavy duty system, it is better to use Sensorless Vector Control (SVC) mode, it will get better output torque performance.
    Before using SVC mode, please perform motor autotunning, do it as below steps:

    1) Set F0-02=0 (keypad), set correct value of F2-01 ~ F2-05 (based on motor nameplate);
    2) If the load can be removed from motor, please set F2-11=2 (Rotation autotuning, get better performance), if the
    load cannot be removed from motor, please set F2-11=1 (Static autotuning). The keypad will display “TUNE”.
    3) Press the RUN button, wait until the autotuning finish automatically.
    4) Change the value of F0-01=0 (Sensorless vector control)

    3.5 Parameters setting

    No.Function codesDefaultSetting valueExplanation
    1F0-0120Sensorless Vector Control
    2F0-0201External singal start / stop
    3F0-0316Multi-step speed
    4F0-17Model depend5sAcceleration time (adjustable)
    5F0-18Model depend0.5sDeceleration time (adjustable)
    6F3-10150%200%Torque uppee limit
    7F5-0011Forward
    8F5-0122Reverse
    9F5-02012Multi-step speed termnial 1
    10F5-03013Multi-step speed termnial 2
    11F5-04014Multi-step speed termnial 3
    12F6-0222Fault output
    13F6-0503FDT1 output
    14F8-1950.00Hz3.00HzSetting FDT1 output frequency
    15FD-000.00%16%Multi-step speed 0 (adjustable)
    16FD-010.00%16%Multi-step speed 1 (adjustable)
    17FD-020.00%30%Multi-step speed 2 (adjustable)
    18FD-030.00%50%Multi-step speed 3 (adjustable)
    19FD-040.00%70%Multi-step speed 4 (adjustable)
    20FD-050.00%82%Multi-step speed 5 (adjustable)

    3. 6 Problems faced during commissioning

    (1) For KD330-09000T4, it needs connect additional braking unit and braking resistor to consume the regenerated
    energy. The parameter of FA-04 is the braking threshold, the default value is 135%. The stand DC bus voltage is
    540V, 540*135%=729V, that means while the DC bus voltage reach to 729V, the Braking unit will start work.
    Sometimes, the fault of over voltage will happen, please reduce the value of FA-04 to avoid it.

    (2) Cause the tower working distance is too long, during down running, the inverter works at regenerated status for long time, so the braking resistor should be selected bigger, to get better performance. In this system, it is
    select as 4ohm, 10kW.