Item | Technical Index | Specification |
|
Input | Input voltage | 1AC 220~240V±15% |
3AC 220~240V±15% |
3AC 380~460V±15% |
Input frequency | 50/60Hz±5% |
Output | Output voltage | 0~rated input voltage |
Output frequency | 0~6000Hz |
Control Features | Control mode | V/f control |
Sensorless vector control |
Torque control |
Overload capacity | 150% / 120s, 160% / 60s, 180% / 10s, 200% / 1s. |
Frequency accuracy | Digital setting: 0.01Hz |
Analog setting: maximum frequency ×0.05% |
Starting torque | 0.5Hz/180% (SVC); 1Hz/150% (V/f) |
Speed control precision | ±0.5% (SVC) |
Carrier frequency | temperature and load characteristics 0.5~16.0kHz, automatically
adjusted according to |
|
Frequency setting mode | Digital setting, analog setting, pulse frequency setting, serial
communication setting, multi-step speed setting & simple PLC, PID
setting, etc. These frequency settings can be combinated & switched
in various modes. |
|
|
|
Torque boost | Automatically torque boost; manually torque boost: 0.1%~30.0 |
|
Operation command mode | Keypad control |
Terminal control |
Serial communication control (Modbus) |
Acceleration/deceleration mode | Straight line/S curve; four kinds of acceleration/deceleration
time, range: 0.0s~65000s |
|
V/f curve | Three types: linear, multiple point and square type (1.2 power, 1.4
power, 1.6 power, 1.8 power, square) |
|
Acceleration/deceleration mode | Straight line/S curve; four kinds of acceleration/deceleration |
time, range: 0.0s~65000s |
Braking unit | build-in standard. |
DC braking | Braking time: 0.0s~25.0s |
DC braking when starting and stopping |
DC braking frequency: 0.0Hz~maximum frequency |
Simple PLC & multi-step speed operation | It can realize a maximum of 16 multi-step speeds running via the
built-in PLC or control terminal. |
|
Built-in PID | Built-in PID control to easily realize the close loop control of
the process parameters (such as pressure, temperature, flow, etc.) |
|
|
Automatic voltage regulation | Keep output voltage constant automatically when input voltage
fluctuating |
|
Control Function | Timing/length/counting control | Timing/length/counting control function |
|
Over-voltage & over-current stall control | Limit current & voltage automatically during the running process,
prevent frequent over-current & over-voltage tripping |
|
Torque control | Torque control without PG |
Wobble frequency control | Multiple triangular-wave frequency control, special for textile |
Fault protection function | Comprehensive protections include over-current, over-voltage,
under-voltage, overheating, default phase, overload, shortcut,
etc., can record the detailed running data while failures happen. |
|
|
|
Input/output terminals | Communication terminals | Build-in standard RS485 communication interface, support MODBUS-RTU
communication protocol |
|
Input terminals | Programmable digital input: 7 multifunctional inputs, one can be
work as high speed pulse input.3 programmable analog input:AI1,
AI2, AI3: 0~10V / 4~20mA |
|
|
Output terminals | 2 relay outputs, |
2 open collector outputs, |
2 anaalog outputs, 0~10V / 4~20mA |
Human machine interface | LED display | Display frequency setting, output frequency, output voltage,output
current, etc. Two lines display |
|
Environment | Ambient temperature | -10~50°C, without direct sunshine. |
Humidity | 90%RH or less (non-condensing) |
Altitude | ≤1000M: output rated power, >1000M: output derated |
Storage temperature | -20~60°C |
|
| | |
No | Items | KD330 |
1 | Reliable hardware | Only first-class componens are built-in. |
2 | Rubust design | IGBT current > 2 times of inverter output current |
Capacitor > 50uF/A |
3 | Electrostatic testing | 1. Under contact condition -- without failure under 5000V. |
2. Noncontact conditions -- without failure under 10000V. |
4 | High overload capacity | 150% / 120s, 160% / 60s, 180% / 10s, 200% /1s |
Smart start / stop mode | Acceleration / Deceleration time can be set as 0.0s, the inverter
starts and stops the motor as fast as possible without failure. |
|
5 | PCB aging test | 100% test, 50°C, 12 hours. |
Finished products aging test | 100% test, 50°C, 24 hours. |
6 | Loading test | 1. After manufacturing. |
2. After aging test. |
Two times, 100% tested: |
7 | LED display | >7,5kW, two lines parameters dispaly, convenient for
commissioning and operating. |
|
8 | Grouped pulse testing | Without failure under 4500V (better EMC performance). |
|
9 | Big start torque | 0.5Hz/150% (V/f), 1Hz/150% (SVC) |
10 | EMC filter | C3 level EMC filter build-in standardly |